The SonarCE application is a real sonar based on Pocket PC device. It uses the internal Pocket PC sound system to detect echo from different obstructions. It is quite precise with error of 5-10 cm at distance of 10m in air. It can be use in air or in water but in case of water you need external microphone and speaker closed in water proof case. The main window toolbar contains the most important functions: send one chirp, sonar loop and analyze window. More advanced functions are hidden under settings menu. Additionally this program is equipped with testing functions which helps to test the device parameters crucial for the Sonar CE application.
Physical background
The short sound (chirp) is sent by the speaker in interesting direction. When the sound “finds” on its way any obstruction, then is reflected and comes back to the device’s microphone. The device is in recording mode (after sending a chirp) and records the incoming sound wave. The recorded wave is correlated with the output signal (played sound data). If the recorded data have the same or similar course as played signal then the autocorrelation function returns maximum. Unfortunately the recorded signal is deformatted by the sound line (amplifiers, speakers, microphone and digitalization) and thus is not really the same. Additionally the correlation function itself generates sinusoid like course (due to its mathematical properties) thus the correlation data needs a post processing. The correlation function can be improved by played the sound with different frequencies within the played time (1). This make the autocorrelation function more sharp. The post processing function takes absolute value from the correlation function and reduces the output data to less points (230 in this case). Every point represents the maximum value from the window operating on correlation function. For example, if the correlation function has 2300 points and the data window is 10 points wide then the first point from post processing data represents the maximum value from the first 10 point (of the absolute values) of the correlation data. The absolute distance measured by any sonar depends on the time the chirp is played (longer time more sound energy is cumulated in the chirp), from sound amplitude and in small degree from chirp frequency (different absorption wave in different medium eg. low freq. waves can travel longer).
Like it? Share with your friends!
If you got an error while installing Themes, Software or Games, please, read FAQ.
Supported operating systems:
Pocket PC 2002, Windows Mobile 2003, Windows Mobile 5.0
Similar Software:
Super Ruler Super Ruler - With this screen you will find a precise display of centimeters and inches on your Pocket PC. You must want to make sure how to offer the same scales on different machines with different pixels and different screen sizes. We afford options of common screen sizes in the setting menu, such as 3.5 inch, 3
iFD Bundle iFD Bundle Basic arithmetic operations, Logarithmic functions, Trigonometric functions, Arc functions, Power functions, Root functions, Factorials, Reciprocal functions, Working with memory locations, Converting of numbers, Controlling the precision, Constants, Language options, skins. Charts from various functions
Electrical Engineering Guide Electrical Engineering Guide - EE Guide for the following: -Resistor Color Guide -Inductor Color Guide -Logic Gates w/Truth Tables -4000/7400 IC Family List & Description -Ohms Law Equations Will work with most PocketPC Devices that supports the DotNET Compact Framework. All CPUs supported are included in the download file
ScrewGuide ScrewGuide - This program is a reference to the types of screws and screwdrivers for wood and metal.
This program requires that you have both the 'BeanDLL.dll' file ** and ** the runtime files for Visual Basic on your PocketPC computer. Simply unzip the file for your processor and place the DLL file in the 'Windows' folder of your PocketPC computer
Dog Leg Severity Dog Leg Severity was developed for engineers in the field who want a good estimation of the True Vertical Depth and Dog Leg Severity inside of a well. The engineers can use the Well Survey points to enter the Measured Depth, Inclination and Azimuth to calculate the estimated True Vertical Depth and Dog Leg Severity based
EngCalc (Electrical) - Windows Mobile Calculator Software EngCalc (Electrical) - Windows Mobile Calculator Software - A must have for Electrical Engineers. Empower yourself with instant references and solutions of frequently encountered calculation at your finger tips. Just few taps, and all the calculations that consumed lots of efforts and time will vanish, there by increasing efficiency
ConverterCE Pro ConverterCE Pro is a unit conversion program for most commonly used units
S-Calc for the Pocket PC S-Calc for the Pocket PC - Using S-Calc on your Pocket PC you will be able to transform and rotate co-ordinate systems from one base to another, instantly perform setting out (inverse) calculations on data produced or pre-loaded into the Pocket PC
IIR Filter Design Reference for Pocket PC 2002/2003 IIR Filter Design Reference for Pocket PC 2002/2003 - Design IIR filters with required specifications and visualize the Frequency Response, Impulse Response, Phase Plot and Co-efficients with just a click!
Vital Features
Designing Low Pass Filter, High Pass Filter is just with few clicks.
Order of the filter (upto max
Comments on SonarCE:
Comments not found
If you noted an error or download link is broken, please, report it via this page or use comments.
Attention! SonarCE may be not compatible with your device Cingular 8125